jump to contents

KNP - Korea Nuclear Partners Logo

contents

Product To serve as a trustworthy cooperative partner in the global energy market

Monitoring System (I&C)

ERMS Local Control Unit(LCU)

ERMS Local Control Unit(LCU)

Product Details 365 days Non-Stop Operation working in a line with Radiation Meausrement Instrument, Data Aquisition and Storage on a second/minute basis.
– Support Calibration, Operation and Managment of Measurement Instrument
– Using Nulide ROI information, Produce Real-time Statistical Information over cps per each Nuclide.
– Indicate the Interested ROI section on a Spectrum Chart.
– Auto Renewal and Cumulative Display of Counting Rate for Time Diffences of Gamma Spectrum with lines of 44 colors according to Relative Sizes.
Main Customer Korea Hydro & Nuclear Power Co., Ltd.(Kori, Hanbit, Hanwol)
Technical Specification Control and Manage Instrements
– After Automatic Connection with HPIC Detector, Automatically Configure Data Aquisition Preparation.
– After Connecting to NaI(Tl) Detector, Automatically change the Communication Methods in Hi-Voltage Dual Connection upon Communication Problem with LCU
– Channel Shift Autocalibration through Automatic Adjustment over Hi-Voltage and Gain depending on the K-40 Channel shift of Gamma Spectrum from NaI(Tl) Detector.
– Wireless Communication Modem(CDMA) Auto Port Connection and Auto Visual Synchronization
– Auto-Configuration for Data Aquisition after Automatically Connecting Air Collector,UPS and other devices
– Connect Air-Sampler, UPS and Dosimeter to Auto ports and Transmit Data
– Automatically Implement Periodic Visual Synchronization between LCU and Instruments
Data Aquisition and Management
– Store and Manage Data Aquisition considering Dose Rate and States of Instrument through periodic communication with HPIC.
– When operating Programs, Automatically check the chance of HPIC Data Aquisition Failure and Perform Automated Data(not-collected) Recovery
– By Communicating with HPIC, Configuration Information can be Collected, Checked and Changed
– Provide a function to delete Ionization Chamber memory data for a selected period via HPIC communication, with periodic automatic execution based on settings.
– Periodically communicate with the NaI(Tl) detector to collect, store, and manage gamma spectra and equipment status.
– Periodically communicate with the Air Sampler, UPS, Precipitation Gauge, and Surge Protector to collect and manage equipment operational information.
NaI(Tl) Data Auto Analysis
– Automatically process analysis tasks in real-time for every data collection cycle and store results.
– Automatically calculate the count rate from the NaI(Tl) detector's gamma spectrum.
– Automatically convert dose rates and calculate artificial dose rates using various methods based on the NaI(Tl) gamma spectrum.
– Automa
Product Specification + Controller
– ADVANTECH ARK-3500
– Processor
① 4Th Generation IntelⓇ CoreTM i7 : 2.3GHz(Quad Core)
② L3 Cache : 6MB
– Memory : DDR3L 1600MHz, over 8GB
– Graphics
① Intel QM77 Integrated GFX Gen7
② Resolution : 1920 ✕ 1200 @ 60Hz
– Interface
① USB : 6 Port
② RS-232 : 8 Port
③ LAN : 2 Port
④ DIO : More than 1 Port
– SSD : 512GB, 2EA(Dual)
– Others
① Compact Fanless Box PC Type
② Built in Watchdog timer
③ Operating Temperature -20℃ ~ 60℃ @ 5 ~ 85% RH
④ Storage Temperature -40℃ ~ 85℃ (-40℉ ~ 185℉)
⑤ Shock Protection Operating, IEC 60068-2-27
⑥ Vibration Protection Operating, IEC 60068-2-64
⑦ Surge protector Installation
⑧ Power Noise Filter Installation
⑨ Filter Fan Installation for Interior Cooling
⑩ Equipped with a temperature controller (2-Relay System, Digital Temperature ontrol)
+Monitor : 15.6 Wide(TFT LCD)
- Resolution: 1920 X 1080
- Display Colors : 262,144 color
Certification SIREN Lisence Contractor (KINS-RADSEARCH)
SIREN(System for ldentifying Radiation in Environments Nationwide) Program Register
Mobile Radiation Survey Application Program(EMERGLE) Register