Product To serve as a trustworthy cooperative partner in the global energy market

Monitoring System (I&C)

Sample collection facility

Sample collection facility

Product Details - Normal Primary Sampling System(Cooler, Sink, LP)
- Post Accident Sampling System(Rack, Sink, LP)
- Secondary Sampling System(Sink, Sample Pump, LP)
- Radwaste Sampling System(Liquid&Gaseous, LP)
- Applied in water quality analysis sector for automatic measuring and analyzing of nuclear reactor coolant system in 1st nuclear system (NSSS) and steam and circulating water system sample in 2nd system
Main Customer Domestic: Korea Hydro & Nuclear Power

Overseas: UAE BNPP
Technical Specification - Reflected ergonomic design
- ASTM 19.11 based design
- Major device manufacturing technology
(Cooler, Chiller, Resin Column)
- Earthquake-proof grade II design employed
- Operator radiation proof technology
Product Specification ANSI / ANS (N13.1) - Sampling Airborne Radioactive Materials in Nuclear Facilities
ASME (B31.1) - Power Piping
ASME (B31.5) - Refrigeration Piping
Certification KEPIC EN-646
ISO 9001:2008, ISO 14001, OHSAS 18001
ASME U, S, PP