jump to contents
expanded menu
Korea
English
About us
Who we are
CEO's message
Why we are needed
How we organized
Our Shareholders
Main Client
Specialist group
Product
Machineries
Valves
Pumps
Pipes
Heat Exchanger
Crane
Tank,Tray,Rack
Duct
Support
System&Facilities
Fitting
Seals
Filters
Compressor&Actuator
Etc
Electrics
Generator
Cables
Transformer
MCC
Load Center
Light
Batteries
Relays
Etc
I&C
Monitoring System
Indicators, Sensors
Gauges
Etc
Inspection & Services
Mechanical
Electric
Nuclear
Etc
E-catalogue
Contact
Contact
collapse menu
tel
+82-2-6327-8157
email
knp@knp-korea.com
ENG
KOR
ENG
contents
Product
To serve as a trustworthy cooperative partner in the global energy market
Inspection & Services
Machineries
Electrics
I&C
Inspection & Services
Mechanical
Electric
Nuclear
Etc
Home
Product
About Us
Product
Contact
Machineries
Machineries
Electrics
I&C
Inspection & Services
(Inspection & Services)
Search
Catalog Download
Incore instrumentation (DFMS) equipment
This equipment works in the reactor containment building of nuclear power plant and fulfills to withdraw and insert a detector guide thimble that measures neutron distribution inside nuclear reactor.
Detail
Stud bolt cleaning equipment for nuclear reactor
This equipment removes foreign substances and oxidation products around the stud thread of nuclear reactor.
Detail
Fuel Inspection Equipment
As equipment inspecting any defect of fuel cladding tube of nuclear fuel after use, it is composed of visual, ultrasonic inspection.
Detail
Turbine Valve Actuator Tester (TVAT)
It was impossible to diagnose the performance of hydraulic actuator of turbine valve, which is a main core device installed for controlling the amount of evaporator supplied to turbines of nuclear power generation and thermal power generation, without separation from the system. But the present Performance Prediction Diagnostic Tester(TVAT) for Turbine Valve Actuators is improved to be possible this diagnosis. This movable local tester makes the improvement of International creditworthiness to be possible through actual preventive maintenance, integrity evaluation, improvement of power quality, stable power production and reliability securement of maintenance for power generation by pre-performance test about this hydraulic actuator.
Detail
GIS partial discharge detection device of diagnostic equipment
Partially installed sensors to detect any abnormality in the GIS equipment of power plants and substations discharge detection sensitivity of the device, a device for checking the performance and not damaged. The power generation system and the type of synchronization signal simulated partial discharge (corona, Boyd, floating, party table) through the facilities of a data analysis equipment to support efficient management of partial discharge diagnostic system. 1. Create a simulated partial discharge signal (broadband 0.5-1.5GHZ) 2. Power Grid (PT) generated in synchronization with each type of simulated partial discharge signals – Extracting a synchronization signal from the power substation – Create partial discharge type of simulated partial discharge signals 3. The partial discharge test and confirm trends recorded (effective for risk management) – Record Management Checklist for the maintenance of such examination, ensure the normal operation 4. Provide a variety of communication services – Provides RS-232, Ethernet Port for connection of various systems and – It is also associated with other equipment to facilitate the implementation of standard protocols 5. Provide user-friendly UI
Detail
GIS partial discharge diagnostic system
Real-time, online monitoring system for diagnosis of GIS partial discharge phenomena. This system is consist of collecting the partial discharge signal detection ,data monitoring device for acquiring data from the sensor installed in the GIS, analyzing the partial discharge signal, diagnostic server and the communication equipment.
Detail
Simulation testing device for testing inverter control performance (ITS-5000)
Simulation testing device for verifying inverter control performance is a testing device for verifying performance about main functions of inverter system. It is a device that can detect accident wave and card causing failure through main signal monitoring, analysis of inverter main functions and, check inverter system & individual card and record control performance.
Detail
Wireless Dose Monitoring Solution
A Wireless Dose Monitoring Solution is configured to monitor worker exposure dose in real time in any environment without disruption. Intelligent smart helmets with high-performance wireless communication technology are designed to fit radiation control areas and detect hazards through exposure dose and motion of workers, deliver them to managers immediately, and activate alerts quickly. You can also monitor the location of workers, wear dosimeters, and manage access to key areas. This solution provides a wide range of fault-free monitoring environments through a smartphone configured with a PS-LTE network, even in poor communication facilities.
Detail
Electronic Personal Dosimeter (EPD)
EPD Management System dispenses and stores Electronic Personal Dosimeter (EPD). Each Worker can take out or put in an EPD after identification via the system’s personal identification technology. This system is not only ‘ storage system’ but also ‘EPD reader’. At the time of return of an EPD, exposure dose of the worker from the worker’s EPD is transferred to the Data Base, then the EPD is initialized. The system admin can set up multiple EPDs and extract historical exposure data through the system software, and also enhance management efficiency of EPD.
Detail
Smart safety checkpoint for entry into RCA (Radiation Controlled Area)
RCA Access Control System is a smart safety checkpoint for workers upon entry into RCA (Radiation Controlled Area) of nuclear power plant. This system manages radiation exposure dose and radiation worker access into RCA effectively by using dose management software. This system only allows authorized persons based on RWP (Radiation Work Permit), and prevents unauthorized access. When entrance is allowed, dose limit of the selected RWP transferred to EPD (Electronic Personal Dosimeter) and EPD mode is changed into Active mode, and when exit is allowed, exposure dose value is transferred to server computer and EPD mode is changed into pause mode automatically. If worker’s exposure dose exceeds daily limit, RWP limit or annual limit, access of such worker is restricted by the system.
Detail
Inspection before and during operation of nuclear power plant
Inspection of piping, equipment, structure Inspection of Nuclear Reactor container Inspection of heat pipe of steam producer
Detail
IWS (Integrated Wireless System)
1) Model Name : IS-HWT-5000 2) Product Description: The wireless communication network system for nuclear power plants is a self-network using e-Um 5G +PS-LTE + Wi-Fi 6 frequencies, and includes LTE Core System (EPC, UDC, IMS, MCPTT central control devices) and ACCESS network (RU (eNodeB), high-power combiner). Wi-Fi combiner, splitter, integrated antenna)
Detail
Safety-Line Spary
1.The safety-line is sprayed at the sites of construction and manufacturing firms for the laborers and workers to proceed safely. 2.If you spary the nudge escape-line spray product in advance, you can escape safely along the sprayed phosphorescent light without any confusion when emergency occurs. 3.About 60% of the industrial disasters are safety accidents related to slip. You can definitely prevent safety accidents by using the Nudge Non-Slip Spary
Detail
Radioactive Dust Mask
1) The FFP3 mask is applied with ACF-attached fusion material that blocks 99% iodine and fine dust so that it can be used at nuclear power plants and nuclear dismantling sites by improving the convenience of gas masks. 2) FFP2 masks can be used at power generation maintenance sites where many pollutants such as benzene and toluene are generated.
Detail
Passive fire protection, waterproof doors
1. Passive waterproof door of the same shape as normal doors (Securing certain protective function when no compression force is required, a non-powered operation, power failure) 2. Waterproof doors for easy evacuation (domestic and evacuation performance meets NFPA) 3. Earthquake, fire resistance and waterproof doors secured 4. weight: weight gain by distributing the load
Detail
lead blanket, lead vest, waste collection bag, improving safety shoes for radiation area
The lead blanket and lead vest are made with 99.9% of lead, which a user can use with safety and convenience.
Detail